0 INSTALLATION MANUAL Series WARNING; All images and text in this manual is the property of Blitz Co., Ltd. (Japan)
9 SBC i-Color parts list. (Check for all components) Color LCD Display 1Pc Sequential Valve Unit 1Pc CPU Unit 1Pc Main Harness 1Pc Center
10 MMD i-Color parts list. (Check for all components) Color LCD Display 1Pc Center Harness (for SBC) 1Pc Center Harness (for MMD) 1Pc Wiring T
11 1. Display Unit. 2. CPU Unit. (Not included in MMD) Encoder Right Down Switch Left Switch Up Switch MAIN HARNESS CONNECTOR AIR TUBE M
12 4. Harnesses and Connections. SBC i-Color: 5P Harness → Connect to the Main Harness 3P Harness → Connec to the MAP Analyzer (Sold Separately) Φ4
13 Advice Refer to the attached ECU wiring diagram for more information. 5. Installation procedure and method. Warning on installation: 1. Remove
14 Piping methods to the Sequential Valve Unit. Actuator (Swing Valve) Type. 1. Make sure the valve type is set as actuator type (AC) at the contro
15 A Solenoid valve control systems that are common on Nissan and Mitsubishi vehicles. Please remove and plug the hosing that goes to the Solenoid v
16 Waste Gate Type. 1. Make sure the valve type is set as waste gate type (WG) at the controller’s function menu. 2. Take the boost pressure betw
17Installation of the SBC i-Color LCD Display Steps: 1) Disconnect the battery. 2) Connect using the provided T pipe and Φ4 nylon tube from a loc
18Installation of the MMD i-Color LCD Display Steps: 1) Disconnect the battery. 2) Connect the harness from the LCD Display to the center harness
1 First of all Thank you very much for purchasing this product. In order to use this product correctly and safely, please be sure to read this instru
19Initial Setting Basic function. (First of all, carry out the initial setting at the function and calibration mode).
20 Resistance Chart Vehicle Type -2 Mini vans w/ a displacement of less than 1000 cc -1 NA Vehicles fr
21 4) Boost Set Up Select “Boost Setup” at the “CALIBRATION” screen and then press the encoder.
22 MANU (Manual boost set up) 4 different settings can be chosen from 4 different channels (CH). Firs
23Explanation of basic operation and MODE 1. Basic operation Turn the encoder to select and change the values or units. Push (press) the encoder to
24 Boost control functions will not be displayed if used as MMD i-Color. (Only 4 items) 4. Calib Icon A mode to input the initial adjustable v
25Press the RIGHT switch to go back to the ICON MENU. Turn the ENCODER to change the design of the back ground from white → Black → Carbon → B
264. Digital Meter (Dual & Six Fold) Displays in digital and bar graph the selected data sources. The types of display are Dual and Six Fold
27 Record and Replay Function The following functions are only valid at the Dual Digital Meter U
285. Graphic Display. It can be composed of 4 overlapped result graphs. The horizontal axis is the RPM. The graph automatically changes by converti
2 Monitoring functions - Digital display: A total of 12 data (Boost, Tacho, Speed, Power, Temp (Oil/Water), Fuel Press, Oil Press, Data 1 ~ 3 (A sep
29 *Red Mark (Recording) Recorded Memory Fixed horizontal axis RPM Fixed 9-15 scale A/F Air Fuel Ratio Graph Selection o
30 A/F Air Fuel Ratio Graph *Red Mark (Recording) Recorded Memory Fixed horizontal axis RPM Max scale of 1.0 – 2.5 Units in hkPa Max Boo
31 6. Calibration Mode. Initial setting and calibration in using the SBC or MMD ① Speed Calibration A selection of 2P, 4P, 8P, 16P and 40km/h are
32 Explanation of Input Voltage Display Input Line: AUX, DATA1~3 Low Voltage: 0.0~16.0V High Voltage:
33 Advice: It continues to adjust itself even after the self-learning mode (Red CH mark) disappears. The reason for this
34 Co relationship of the Limiter and Warning Limiter ON Limiter OFF Warning Boost Warning is Automatically Turned ON Boost Warning is Autom
35 Press the LEFT switch for over 3 seconds and it will clear the boost peak value. The digital display
36 7. Function Mode. Initial setting and calibration in using the SBC or MMD Example of Source Selection Source: Boost
37Single Warning Dual Warning ② Contrast Adjust from 0~100. Try to adjust so that the black and white can be clearly identified. Changes in
38 ⑥ Peak Mark A setting to display or not to display the blue peak ○ at the Needle Meter. ⑦ Warning Mark A setting to display or not t
3 Advice When on Full Auto Mode for the first time, it will start setting from the original boost pressure in a numbers of attempts. However, if ful
39⑫ Digital Screen Choose from the following three background designs. LOGO Type BLACK Type COMP Type
40Choose the color of the Large size fonts from 10 colors as shown at below dual digital meter. (Ex: Blue Color) Dual Digital
WARNING; All images and text in this manual is the property of Blitz Co., Ltd. (Japan). No part of this maybe reproduced, stored in retrieval systems
4 MMD i-Color Since it is actually calculated on the road, a more accurate reading can be achieved by measuring factors such as frictional resistance
5 The sensors have to be acquired separately. Analog display The TACHO, SPEED, POWER, TEMP (oil/water), FUEL PRESS, OIL PRESS can be displayed as an
6 Safety Notice In order to use the product safely, please read the "SAFETY NOTICE" thoroughly. Explanation of warning symbols DANGER: Ig
7 ・ Disconnect the harness's connectors from the connectors it self. DO NOT pull from the harness. It would cause a fire by an electric short,
8 This product's durability and components are thoroughly tested; however, depending on the vehicle's driven condition and (or) climate,